넳 넲

FC-1100 Acid Mist Suppressant | Copper EW | Highcloud

首页标题  ꄲ  FC-1100 Acid Mist Suppressant | Copper EW | Highcloud

If you run a copper SX-EW tankhouse, you already know the cost of sulfuric acid mist: corroded cranes and busbars, workers reaching for respirators, and environmental readings that keep slipping out of range. FC-1100 is a low-foam, fluorochemical acid mist suppressant developed specifically for copper electrowinning. Dosed at just 10–20 ppm of active solids, it holds sulfuric acid mist below 0.2 mg/m³ — without forming a stable foam blanket and without interfering with solvent extraction or cathode quality. In this article we explain how it works, share its verified technical specifications, and walk through a practical dosing procedure you can apply on your next tankhouse audit.

Why acid mist is a serious problem in SX-EW tankhouses

In copper electrowinning, oxygen evolves continuously at the anode surface. When those bubbles rupture at the electrolyte surface, they throw a fine aerosol of sulfuric acid into the air. The finer the droplets, the longer they stay airborne and the further they travel through the building.

The consequences are well documented in every tankhouse: accelerated corrosion of overhead structures, electrical equipment and crane rails; occupational-health exposure for crane operators and cell crews; and rising pressure from environmental and workplace-safety inspections. Many plants respond with polypropylene microspheres or mechanical covers. These help, but they complicate cell access for harvesting and maintenance — which is why chemistry remains the first line of defense.

How FC-1100 suppresses mist at the source

FC-1100 is a fluorochemical-based suppression additive. Its molecules adsorb at the gas–liquid interface of the oxygen bubbles generated during electrolysis, changing the interfacial mechanics: bubbles rising to the surface do not burst instantly. Instead, electrolyte drains slowly back along the bubble wall, so far fewer fine droplets are ejected into the air. Suppression happens at the source, not after the mist has escaped.

The design goal that matters most to plant engineers is low foam. Conventional surfactant suppressants build a stable foam layer on the cell surface; the active component accumulates in that foam, is gradually stripped away, and mist control drifts within weeks. FC-1100 does not form a stable foam layer on the electrolyte surface. The active components stay in the bulk electrolyte, so inhibition remains stable over the long term and reagent consumption stays predictable.

Key specifications of FC-1100

The table below reflects the specifications published on our official product page. Always confirm the latest values against the current TDS and COA issued with each batch.

Parameter Typical value Note
Appearance Light amber liquid Ready-to-dose formulation
Fluorochemical solid content 45–55% Active suppression component
Moisture 45–55% —
Density 1.2 g/mL —
Viscosity < 100 cP Easy pumping and metering
Recommended dosage 10–20 ppm active solids Electrowinning service
Acid mist level achieved < 0.2 mg/m³ At recommended dosage
Flash point None Non-flammable handling
Foam behavior Low foam No stable foam layer on cells

If you need a parameter that is not listed here — for example freeze point or compatibility data with your specific extractant — ask us; anything not yet verified on the TDS is marked "to be confirmed" rather than estimated.

How to dose FC-1100 in your plant

  1. Inject upstream of circulation. Add FC-1100 at the suction side of the electrolyte circulation pump so it mixes fully before reaching the cells. This gives uniform concentration across the whole tankhouse.
  2. Start low, verify, adjust. Begin at 10 ppm and measure mist at breathing height over representative cells. Increase toward 20 ppm only if readings stay above your target.
  3. Combine with mechanical barriers if you wish. FC-1100 can be dosed alone or alongside polypropylene microspheres for plants that keep both systems in place.
  4. Re-check after process changes. Current density, electrolyte temperature and acid concentration all affect mist generation — re-verify after any significant change.

At recommended dosage, FC-1100 does not negatively affect the solvent extraction or copper electrowinning process and does not change cathode copper quality. We still recommend a bench-scale trial on your electrolyte before full-scale dosing — we support it with samples and technical follow-up.

Applications beyond copper

The same suppression chemistry applies to electrowinning and electrorefining systems for nickel, cobalt and zinc, and it is compatible with high-concentration sulfuric acid electrolytes. For smelters under tightening occupational-health and emission requirements, one dosing point at the circulation pump is often the most economical retrofit available.

FAQ

Will FC-1100 form a persistent foam layer on the cells? No. Its low-foam formulation avoids the stable foam blanket typical of conventional surfactants, which prevents active-component loss and keeps long-term suppression stable.

Does it affect copper cathode quality or the SX circuit? At the recommended dosage it is designed not to interfere with either. Confirm with a bench test on your own electrolyte; we provide samples for this purpose.

What is the packaging and lead time? Export-standard packaging is available; exact drum/IBC configuration and current lead time are to be confirmed with our sales team when you request a quote.

Can it be used in nickel, cobalt or zinc electrowinning? Yes. It suits non-ferrous electrowinning systems operating on high-concentration sulfuric acid electrolyte.

Why Qingdao Highcloud Materials

Qingdao Highcloud Materials Co., Ltd. manufactures acid mist suppressants alongside a broad magnesium-chemicals portfolio — magnesium sulfate, magnesium hydroxide, magnesium oxide — plus fine chemicals such as bismaleimide (BMI) resins and epoxy curing agents. We export worldwide from Qingdao, operate under an ISO 14001 (GB/T 24001-2016) environmental management system, and support every shipment with TDS, COA/SDS documentation and pre-scale-up sample testing. Our engineers work directly with your plant team on dosing trials and follow-up measurements.

Ready to cut acid mist in your tankhouse? Request a quote / Get TDS & COA — or WhatsApp us directly: +86 158 6406 7774

Related resources

2026年11月2日 12:37
ꄘ浏览量:0